OCS240/241 Chlorine Dioxide |
Product description
The OCS240/241 is a membrane covered, amperometric sensor for installation in flow assembly OCA250. The chlorine dioxide sensor has been specifically designed for applications with a measuring range between 0.05 ... 20 mg CIO2/l (ppm).
Your benefits:
Minimum flow rate for installation in the OCA250 flow assembly: 30 l/h
Measurement almost independent of flow rate in the range above 30 l/h
No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine dioxide sensors, is not necessary.
Measured values are not affected by conductivity fluctuation.
The OCS240 sensor is ready for measurement after a polarisation time of approx. 10 ... 30 minutes. The OCS241 sensor requires 45 ... 90 min.
Easy membrane replacement thanks to ready-made membrane head
Recalibration intervals approx. 1 ... 4 months under constant operating conditions
Back pressure up to 1 bar / 14.5 psi allowed at the outlet
Field of application
Chlorine dioxide is used for disinfection of water. Its dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable. Too high a concentration can result in corrosion effects, impairment of taste or skin irritation. The OCS240/241 sensors are applied for measurement of chlorine dioxide in the following fields: